480

Commenting on behalf of

Geoquest Canada

Comment status

Comment approved More about comment statuses
Please see attached comments regarding the following key points: 1) OPSS 1355.05.03 - Associated Hardware 2) OPSS 1355.07.11.03 - Formwork Removal During Curing 3) OPSS 1355.07.11.04 c) - Records of Inspection of Moist Curing Read more

Comment ID

493

Commenting on behalf of

Miller Paving Ltd. / Redi Rock Retaining Wall Systems

Comment status

Comment approved More about comment statuses
If empirical data can be provided, eg side by side comparisons of moist cured vs. non moist cured elements to demonstrate the absence of shrinkage/cracking and to compare concrete strengths, could a clause be added to provide for the removal of the moist curing requirement at the owners discretion? Read more

Comment ID

500

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
1355.07.13.03 Temperature Monitoring Records PH-CC-117 (COLD WEATHER CONCRETING TEMPERATURE RECORD) form applies to cast-in-place construction not indoor precast plants. Temperature monitoring data is provided from thermocouples. This should be removed from the precast specification. Read more

Comment ID

501

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
1355.07.24 Manufacturer’s Certificate of Conformance One C of C should be issued for all the elements being delivered to a project or site, not each individual shipment. The elements covered can be listed on the single C of C. Read more