This consultation was open from:
July 16, 2026
to August 13, 2026
Decision summary
Following industry consultations, the draft of Structural Standard Drawings listed below have been updated
to address feedback:
S 110-4110
S110-4510
S110-4710
S110-4720
S110-5110
S110-5120
S110-5210
S110-5510
S110-5710
S110-5720
S110-5810
S110-6210
MTOD 3960.200.
These drawings will be published on the MTO’s Technical Publication website and implemented in CPS.
Decision details
The MTO has addressed feedback received through the TCP consultation by making fine improvements on the drawings. All drawings have been finalized for publication on the MTO’s Technical Publication site and for implementation in CPS.
Effects of consultation
Few updates were made by clear labeling on the drawings and to maintain consistency between all SSDS.
Supporting materials
Connect with us
Original proposal
Proposal details
Package #1 (S110-4710,110-4720,110-5710,110-5720):
This package includes new set of Structural Standard Drawings for MASH TL 4 & TL 5 Moment Slab
Designs for MSE walls applications. These drawings are developed using both stainless steel (SS) and
GFRP reinforcement. The designs are based on a review of NCHRP Reports 326 and 1078, AASHTO LRFD
(2024), and CSA S6:25, with modifications to align with current reinforcement requirements.
Design tables are provided to assist designers in selecting appropriate slab dimensions. The Standard
Special Details (SSD) also include requirements for the MSE wall designer to account for impact loading
effects on the internal stability of the wall.
Package #2 (S110-5110,110-5120,110-5510):
This package comprises three SSDs, including a TL-5 MASH-equivalent parapet wall barrier with two-tube
railings designed with reinforcement options utilizing either GFRP or stainless-steel rebar. Standard
drawings for a TL-5 MASH-equivalent steel
Package #3(S110-4110 ,110-4510):
This package consists of a TL-4 MASH-equivalent parapet wall barrier with two-tube railings, reinforced with
GFRP rebar. Standard drawings for a TL-4 MASH-equivalent steel two-tube railing is also included in this
package.
Package #4 ((S110-5810,110-6210):
This package includes structural standard drawings for:
• Asymmetric Barrier with Moment Slab (to be used on highway for protection of structures
•Tall Barrier Wall without Railing, TL6 (this SSD is created for the sites where twining of bridges is required)
MTOD 3960.200 is added. This MTOD is a common reference to all SSD packages posted in this
submission. The drawing contains the standard details of barrier control joint & expansion joint.
Supporting materials
Comment
Commenting is now closed.
This consultation was open from July 16, 2026
to August 13, 2026
Comments received
Through the portal
3