Commentaire
910.05.03.01
“The pre-packaged dry grout mixtures shall be used within 6 months of packaging and shall be stored on site for a maximum of 1 month”
- duration on site should be increased to 6 months, with proper storage conditions
910.06.02 Grouting equipment
“Calibrated within a 6 month period preceding the work. The device shall be accompanied by a certified calibration curve that bears the seal and signature of an Engineer”
- It is not understood what needs to be calibrated in a grouting pump. It should be removed
Submitted 15 mars 2023 1:56 PM
Commenter
OPSS 910 - Spécification de construction pour les systèmes de précontrainte par post-tension
PCT Numéro
000-0139
commentaire ID
309
Commentant au nom de
État du commentaire