Comment
910.05.03.01
“The pre-packaged dry grout mixtures shall be used within 6 months of packaging and shall be stored on site for a maximum of 1 month”
- duration on site should be increased to 6 months, with proper storage conditions
910.06.02 Grouting equipment
“Calibrated within a 6 month period preceding the work. The device shall be accompanied by a certified calibration curve that bears the seal and signature of an Engineer”
- It is not understood what needs to be calibrated in a grouting pump. It should be removed
Submitted March 15, 2023 1:56 PM
Comment on
OPSS 910 Construction Specification for Stressing Systems for Post-Tensioning
TCP number
000-0139
Comment ID
309
Commenting on behalf of
Comment status