910.06.04 “Each gauge shall…

TCP number

000-0139

Comment ID

301

Commenting on behalf of

VSL

Comment status

Comment approved More about comment statuses

Comment

910.06.04
“Each gauge shall be capable of indicating forces directly in Newtons or be accompanied by a conversion chart so that the imperial readings can be converted into Newtons”
- Gauges usually indicate pressure, not Force. This allows use of same calibrated set of pump and gauge with different hydraulic jacks (different ram areas) . A conversion chart must be provided

“Each gauge shall be accompanied by a certified calibration curve that bears the seal and signature of an Engineer.”
- Calibration curves must be certified by a third party. Stamping and sealing by an engineer can be logistically challenging/impossible, depending on the specific requirements of laboratories