910.05.02.03 “Ducts at…

TCP number

000-0139

Comment ID

298

Commenting on behalf of

VSL

Comment status

Comment approved More about comment statuses

Comment

910.05.02.03
“Ducts at Deviators
Ducts within a deviator for post-tensioning tendons shall be galvanized steel pipe according to ASTM A53,Type E, Grade B, with a wall thickness of not less than 3 mm. The duct shall be formed to conform to the alignment of the tendon.”
- Does it refers to external tendons? If so, out of scope of the standard, as per 910.01