Clause 1350.07.04.02…

PCT Numéro

000-0288

Comment ID

552

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses

Commentaire

Clause 1350.07.04.02 Discharge Time

When concrete or OGDL is transported by means of non-agitating equipment, discharge shall be completed within 30 minutes after introduction of the mixing water to the cement and aggregates.

30 minutes for OGDL is too narrow of a window, if there is any traffic, the trucks will be late. OGDL doesn't have a strength requirement and even if it did, it would be in the 1-5 MPa range at 7 days. It is a stabilized granular, it is not expected to have significant structural capacity. Even at 1 MPa it stronger than a Granular base. The structural layer coefficient is in the range of 0.2-0.27 (CPTechcentre Guide for FDR) but in the design manual we only use 0.14 for PC stabilized OGDL.