Commentaire
There is a discrepancy between Figure 8.1.1 and the corresponding text under Section 8.1.2 n) where 2mm is shown in the figure while the corresponding text states 1.5mm section loss to be assumed.
Submitted 1 décembre 2023 9:15 AM
There is a discrepancy between Figure 8.1.1 and the corresponding text under Section 8.1.2 n) where 2mm is shown in the figure while the corresponding text states 1.5mm section loss to be assumed.
Submitted 1 décembre 2023 9:15 AM
Commenter
Manuel de conception des structures v60
PCT Numéro
000-0184
commentaire ID
399
Commentant au nom de
État du commentaire